On an Active Smart unit, 6 tells you the freezer (FC) sensor resistance has dropped below 660 ohms, which is outside the normal range. Think of it as the opposite end of code 5 for the same sensor.
At a glance
| Code | 6 |
|---|---|
| Appliance | Freezers |
| What it means | The FC (freezer) sensor resistance is outside the normal range, below 660 ohms. |
Is the freezer too warm?
Not necessarily. Resistance falls as the sensor warms, per the manual’s table, but the manual frames the fault as a sensor resistance problem. Its table bottoms out at 0.9106K ohms for 50 degrees C. A value under 660 ohms is beyond that, which a real freezer compartment should never reach.
Fix path in the manual
- Primary action: check the sensor connection at the power module.
- Secondary action: replace the sensor.
Nothing else is given for this code, and the manual does not list any step for the owner.
Practical notes
Whatever you do, the alarm can be muted by pressing any button, but it will keep returning with the flashing fault pattern until the cause is dealt with. If food is at risk while you wait, moving it to another freezer is simple sense and does not depend on the code.
Related sensor codes
- Code 5: FC sensor above the normal range
- Code 4: all sensors below 660 ohms
- Code 10: the PC (fresh food) sensor below range
Fisher & Paykel freezer visits in San Francisco
Reach us on (415) 941-6957. Give the code, the model number and what the freezer temperature feels like.