Too much current through a heater usually means the electrical path has become shorter than designed. That is what code 14 reports for the low ambient heater in a Fisher & Paykel Active Smart refrigerator: either a short somewhere in the heater or its wiring, or a heater that has simply gone bad.
At a glance
| Code | 14 |
|---|---|
| Appliance | Refrigerators |
| What it means | The low ambient heater is drawing more current than expected, from a short in the heater or wiring or a faulty heater. |
Compare with code 13
| Code 13 | Code 14 | |
|---|---|---|
| Current | Lower than expected | Higher than expected |
| Wiring fault named | Open circuit | Short |
| Heater fault named | Faulty heater | Faulty heater |
Both appear in the manual with the same two follow-up steps, so the technician does the same job and simply knows which direction to expect.
What gets done on a service call
The manual starts with the wiring and the connections at the heater end and at the power module end. Next comes the heater’s resistance. If it does not fall inside the stated limits, the heater is replaced. Nothing in the manual suggests an owner-side fix.
Safety thinking
A short in a heater circuit is exactly the kind of fault where you should leave the covers on. If you notice a burning smell, scorched plastic or a tripping breaker, unplug the refrigerator and move the food elsewhere. A calm display of code 14 with no other signs is less urgent, but it should still be looked at, since the alarm resets itself after 72 hours unless power is disconnected for a few seconds.
See also
- Code 13: this heater with too little current.
- Code 12: heater and both fans reading high together.
- Code 16: a fan with the same high-current pattern.
Book Fisher & Paykel repair in San Francisco
For code 14, phone (415) 941-6957. We will ask for the model number and the code, and whether you smelled anything unusual.