Fault 4 is the low-resistance twin of code 3. The control finds the resistance of every temperature sensor outside the normal range, this time below 660 ohms. Because it hits all the sensors together, the manual does not send anyone to the individual sensors.
At a glance
| Code | 4 |
|---|---|
| Appliance | Freezers |
| What it means | The resistance of all the temperature sensors is outside the normal range, below 660 ohms. |
What the manual lists
| Order | Action |
|---|---|
| Primary | Check the 6 way RAST connector at the power module |
| Secondary | Reterminate the 6 way RAST connector |
| Tertiary | Replace the power module |
Scale of the reading
In the manual’s resistance table, the warmest entry is 50 degrees C at 0.9106K ohms, which is about 910 ohms. A reading under 660 ohms is lower than that, so it sits outside the table entirely. For comparison, the table gives 2.186K ohms at 25 degrees C.
What an owner can do
Very little, and that is by design: the parts involved are a wiring connector and the power module. You can stop the alarm with a button press, or by disconnecting the appliance from the power supply for a few seconds, and you can record the LED pattern. Then arrange service.
If the unit has just been switched on or a door has just closed, give it 20 seconds with doors shut so its self-test can finish before you trust any code.