The low ambient heater (often shortened to LAH) is a small heating element in the fridge. Code 13 says it is not drawing as much current as the control expects. The manual gives two reasons: the heater or its wiring is an open circuit, which means a break in the path, or the heater itself is faulty.
At a glance
| Code | 13 |
|---|---|
| Appliance | Refrigerators |
| What it means | The low ambient heater is drawing less current than expected, from an open circuit in the heater or wiring or a faulty heater. |
| First thing to try | Inspect the wiring and connections at both ends, at the heater and at the power module. |
Order of checks in the manual
- Inspect the wiring and connections at both ends, at the heater and at the power module.
- Measure the ambient heater’s resistance. If it is outside the limits, replace the heater.
That second step takes a multimeter and the published resistance limits, so it belongs to a technician.
A false alarm you can avoid
This is the first item in the fridge’s 20-second power-up test. Suppose the fan/heater connector at the power module is unplugged and a door is opened the instant the alarm sounds. The test stops early, and the code shown is 13. Leave the doors shut until the tests complete and the code reads 11 instead.
Practical advice
Do not try to test the heater by hand; the manual treats this as technician work. What you can do is note whether the code appeared right at start-up or later, press a button to hush the alarm, and arrange a visit.
Cousins of this code
- Code 14: the same heater, but drawing too much current.
- Code 11: heater and both fans reading low together.
Fisher & Paykel refrigerator service in San Francisco
Call (415) 941-6957 and give us your model number, the code, and whether it showed on power-up.