Source: Fisher & Paykel Active Smart Refrigerators USA service manual 517775 (August 2004), section 1.0 Fault Code Display Status (Stage 4.2); hosted on uncleharrywizard.com

Error code 10
Appliance Freezers

Code 10 is about the fresh food compartment. In Fisher & Paykel’s Active Smart service manual, “PC” is the fresh food side and its temperature sensor is a thermistor, a part whose electrical resistance changes with temperature. Code 10 says that resistance has fallen below 660 ohms, which is outside the normal range.

At a glance

Code10
ApplianceFreezers
What it meansPC (fresh food) sensor resistance is below the normal range (below 660 ohms).

What the numbers mean

ReadingCompared with the manual’s table
Normal sensor25.17 kilohms at -30 C down to 0.9106 kilohms at 50 C
Code 10Below 0.66 kilohms, under the bottom of the table
Code 9 (opposite fault)Above 45 kilohms, over the top of the table

A reading that low does not correspond to any real temperature in the compartment, which is why the controller treats it as a sensor or wiring fault and not as a warm refrigerator. The manual gives no cause beyond the out-of-range reading.

Order of work for the technician

  1. Check the sensor connection at the power module.
  2. If the connection is good, replace the sensor.

The manual also describes a diagnostic mode that shows the PC sensor temperature as an LED pattern: add up the lit values and subtract 40 to get degrees Celsius. This is a technician tool, and readings change fast once the door is open.

Safe steps for you

  • Press any control button to quiet the alarm, or unplug for a few seconds to reset it.
  • Do not pull on sensor wires inside the compartment.
  • Check food temperature by other means while the fault is active.

Sensor codes to compare

  • Code 9: the same PC sensor reading too high
  • Code 6: the freezer (FC) sensor reading too low
  • Code 4: all sensors too low at once

Fridge and freezer sensor service in San Francisco

Call (415) 941-6957 with the code number from the LEDs and tell us if the fresh food side is running too warm or too cold.

Plain language

What this code means

PC (fresh food) sensor resistance is below the normal range (below 660 ohms).

Ready to get your Fisher & Paykel appliance working again?

Book a repair online or call us — clear estimates and approval before any repair work begins.

Book a repair

Tell us what’s wrong — we’ll take it from there

Share a few details and we’ll confirm an appointment. Prefer to talk? Call us and we’ll help right away.

Hours Mon–Sat: 8:00 AM – 7:00 PM
Service area San Francisco Bay Area, California

Request your repair

(415) 941-6957 Book a Repair