The freezer compartment sensor, called the FC sensor, is behind code 5. Its resistance is above 45K ohms, outside the normal range. Only this sensor is named, so the fault is narrower than code 3, where every sensor is affected.
At a glance
| Code | 5 |
|---|---|
| Appliance | Freezers |
| What it means | The FC (freezer) sensor resistance is outside the normal range, above 45K ohms. |
Reasoning behind the readings
The sensors are thermistors, which change resistance with temperature. In the service manual’s table a sensor reads 25.17K ohms at -30 degrees C and drops to 6.000K ohms at 0 degrees C. A value above 45K is outside the manual’s table.
Technician sequence
- Look at the sensor connection at the power module.
- If that is sound, replace the sensor.
Reading the temperature directly
Technicians can enter a diagnostic mode by holding MODE and pressing the temperature UP button. The first screen is the PC sensor temperature; one more press of UP shows the FC sensor. The temperature is the sum of the lit LED values minus 40. The mode times out after 5 minutes if not exited, and door alarms do not operate while it is active. This is a service procedure, so use it only if you were told to.
Nearby codes
- Code 6: the same FC sensor, below the normal range
- Code 9: the PC (fresh food) sensor, above range
- Code 3: all sensors above range
Freezer sensor help in San Francisco
Call (415) 941-6957 with the code and model number of your Fisher & Paykel unit.