Most sensor codes name one sensor. Code 3 does not: the control reports that the resistance of all the temperature sensors is outside the normal range, specifically above 45K ohms. The manual’s actions below all point at the shared connector and the power module, not at any single sensor.
At a glance
| Code | 3 |
|---|---|
| Appliance | Freezers |
| What it means | The resistance of all the temperature sensors is outside the normal range, above 45K ohms. |
| First thing to try | Primary: check the 6 way RAST connector at the power module. |
Three-step action list
- Primary: check the 6 way RAST connector at the power module.
- Secondary: reterminate that 6 way RAST connector.
- Tertiary: replace the power module.
The manual lists the three actions in this order.
How high is 45K?
The manual’s thermistor table runs from -30 degrees C, where a sensor should read about 25.17K ohms, down to 0.9106K ohms at 50 degrees C. Resistance falls as the temperature rises. A reading above 45K is beyond the cold end of that table, which is far from anything a working kitchen freezer sensor should report.
Not an owner repair
The connector lives at the power module. Leave that to a technician. What you can do is press a button to quiet the alarm and note the flashing LED pattern.
Companion codes
- Code 4: all sensors again, but below 660 ohms
- Code 1: the power module failed its self-test on the last power-up
- Code 9: only the PC sensor reads above range