A fault code 1 on a Fisher & Paykel Active Smart refrigerator-freezer means that when the appliance last powered up, its power module ran a self-test and did not pass. The 2004 service manual for these units gives the code a single reason and a single action: replace the power module.
At a glance
| Code | 1 |
|---|---|
| Appliance | Freezers |
| What it means | On the last power up, the power module failed its self-test. |
How the code reaches you
The appliance shows faults on its display automatically and sounds an audio alarm. The bottom LED flashes red, alternating with the LED pattern that stands for the code. Pressing a control button silences the alarm, and the normal display returns for 8 seconds before the code resumes flashing.
The code itself is binary. Each LED stands for a value and the lit ones are added up. The manual’s example, with LEDs worth 2 and 16 lit, reads as code 18.
What an owner can do
- To reset the audio alarm, disconnect the appliance from the power supply for a few seconds. Otherwise it stops by itself after 72 hours.
- Leave the door closed as much as possible. The food compartments depend on the appliance running.
- Contact service and give the code number.
What the manual tells a technician
The page lists a primary action only: replace the power module. There is no checking sequence, no connector to reterminate, and no secondary step, unlike most of the other codes.
Where this sits among the codes
Codes 2 to 18 cover defrost, sensors, heater and fans. Code 1 stands apart because it concerns the module that measures all of them. See code 3, where every sensor reads out of range at once, which can also point to the power module.
Refrigerator-freezer service in San Francisco
To report a code 1, call (415) 941-6957. Say what the LEDs show, and whether the alarm sounded right after a power cut or after you plugged it back in.