A gas burner that clicks after lighting is often a misaligned cap or damp ports. Dry and reseat the cap before assuming an ignition fault.

Written for Fisher & Paykel owners

A Fisher & Paykel gas burner that keeps clicking after it has lit is most often being told it has no flame, because the burner cap is misaligned, the ports are wet or dirty, or the igniter is damp, and the spark keeps trying. Turn the burner off, dry and reseat the cap, and try again before assuming the ignition system has failed.

Why the click continues after the flame is there

On a Fisher & Paykel gas range or cooktop, the spark igniter clicks until the control senses a flame. A burner that is lit but still clicking suggests the flame is not reaching the point the control checks, or that something is giving the spark a path to keep going. It can also mean the burner never truly caught and only appeared to for a moment. Watch the burner closely: does the flame sit evenly around the whole ring, or does it lift, flicker or burn only on one side?

Note whether the clicking stops when you turn the knob down to a lower setting, whether it affects one burner or all of them, and whether the sound is a steady tick or a fast rattle. Those details help separate a local problem at one burner from a shared one.

Cap, base and ports on a sealed burner

The RDV2-366-N_N dual fuel range, a 36-inch Series 9 Professional with six Sealed Dual Flow Burners, is a good example of why placement matters. A sealed burner relies on the cap sitting flat and square on its base, so the gas ports line up with the igniter and the flame sensing area. A cap that is slightly off, or one put back on the wrong base after cleaning, can leave the flame too far from the igniter.

  • Turn every burner off and let the cooktop cool completely.
  • Lift off the cap and check it is dry, with ports free of food, grease and cleaning residue.
  • Look at the igniter tip beside the burner base and make sure it is not coated.
  • Set the cap back down so it sits flat, without rocking, then try again.

Wet ports are a very common cause after a wipe-down. Leave the caps off to dry for a while, and do not use a pin or a wire to clear the ports, which can enlarge them.

Moisture, spills and nearby surfaces

A spill that has run under a cap or around the igniter can give the spark a damp path to ground, which keeps it clicking. Boil-overs on a continuous grate surface such as the one listed for the CDV3-365-N, a 36-inch Series 7 Professional gas cooktop with five Sealed Dual Flow Burners and continuous surface grates, may travel underneath before you notice. After a spill, clean around the base with a soft damp cloth when everything is cold, then dry it thoroughly.

If the clicking began after heavy cleaning, after a power cut, or after moving the appliance, tell us. It narrows the possibilities a good deal.

If your cooktop shows a code

Gas burners rarely show codes, but combined units and ranges with displays can. For cooktops the library lists E1 and E2 as a problem with the power supply, and E3 and E4 as an overheated cooktop. The matching pages on this site are cooktop E1 and E3. Check that the unit has power and that the breaker has not tripped, then let a hot unit cool before restarting. If you see EX03, listed as an electronic board or software error, that is not a cap or moisture problem and needs a technician. Do not guess at a code that is not on your display, and write down exactly what it shows.

What owner checks cannot rule out

Drying and reseating the burner can end continuous clicking, and that is a good result. It cannot prove that the igniter is intact, that the ignition module is producing a clean spark, or that the gas supply to that burner is steady. It also cannot tell you whether a burner that clicks even though the cap and ports are clean has a wiring fault or a control problem. Do not attempt to adjust gas valves, remove the cooktop, or work with the gas line.

If you smell gas, do not operate any control or switch. Leave the area and call your gas utility from outside. A burner that clicks but does not ignite for more than a short time should also be switched off, with the room ventilated, before you try anything else.

What to have ready when you book

Give us the Fisher & Paykel model and serial number from the rating label, which burner clicks, whether it lights, what you changed or cleaned beforehand, and any code on display. A Fisher & Paykel technician will test the igniter and its spark, inspect the cap and base, check the ignition module and verify the burner flame. Our range repair and cooktop repair pages describe how we work, and the range reference lists what we service.

Frequently asked questions

Need help with a Fisher & Paykel appliance?

Book a specialist visit for a clear estimate and approval before any repair.

Ready to get your Fisher & Paykel appliance working again?

Book a repair online or call us — clear estimates and approval before any repair work begins.

Book a repair

Tell us what’s wrong — we’ll take it from there

Share a few details and we’ll confirm an appointment. Prefer to talk? Call us and we’ll help right away.

Hours Mon–Sat: 8:00 AM – 7:00 PM
Service area San Francisco Bay Area, California

Request your repair