When the control sees the evaporator sensor under 660 ohms, it raises fault 8. This is the low-side partner of code 7 and uses the identical repair order in the Fisher & Paykel service manual.
At a glance
| Code | 8 |
|---|---|
| Appliance | Freezers |
| What it means | The evaporator sensor resistance is outside the normal range, below 660 ohms. |
Q and A
Does 8 mean the evaporator is overheating?
The manual only says the sensor resistance is outside its normal range. It does not describe the evaporator as hot.
Can I test the sensor myself?
The manual’s thermistor table lists expected resistances such as 6.000K ohms at 0 degrees C and 2.186K ohms at 25 degrees C, but measuring them requires disconnecting the sensor at the power module. That is service work.
What does a technician do about it?
Checks the sensor connection at the power module first, then replaces the sensor.
If you see code 2 as well
The same list of codes includes code 2, where two defrosts in a row were aborted after 30 minutes. If you see both, give the technician both numbers.
Reading the sensor’s temperature
Technicians can read sensor temperatures on the display through a diagnostic mode, entered by holding MODE and pressing the temperature UP button. The mode times out after 5 minutes if not exited. It is a service tool, and the manual notes that door alarms stop working while it is on.
Neighbours
- Code 7: evaporator sensor, high-resistance side
- Code 4: all sensors below range, with a connector-first check
Evaporator sensor faults in San Francisco
For a Fisher & Paykel unit showing 8, ring (415) 941-6957. Have the model number to hand.