If 18 is flashing, the control has measured the FC fan pulling more current than expected. The Active Smart service manual lists shorted wiring or a faulty fan as the reasons. It is the last code in the manual’s fan series, which runs from 15 to 18.
At a glance
| Code | 18 |
|---|---|
| Appliance | Freezers |
| What it means | The FC fan is drawing more current than expected, from shorted wiring or a faulty fan. |
An example from the manual
The manual uses 18 to show how fault codes are read. The LEDs that flash carry binary values, and the two lit ones in its example are worth 2 and 16. Add them and you get 18. So if you are asked to read the lights out to someone, report which LEDs are on, not a guess at the number.
What gets checked
- First, the FC fan wiring and connections, at the fan end and at the power module end.
- Then the fan itself, which is replaced if faulty.
The manual lists nothing for the owner to do, and fans on these units are wired to mains-powered parts. Leave it to service.
Why the wiring comes first
For a fan that draws too much current, the manual separates two culprits: a short in the wiring, or a fan that has failed. The manual lists the wiring check first and the fan check second. Nothing in the manual suggests the problem lies in the freezer contents or the door seals.
Where it sits among the fan codes
If the display instead gives a combined reading, see code 12, where heater and both fans together draw more than expected.
Fisher & Paykel freezer help in San Francisco
Our line is (415) 941-6957. Tell us the code and the model, and mention if the alarm has been silenced.