A 16 on the display is the high-current partner of code 15. Both concern the PC fan, the fresh food compartment fan. Here the control sees the fan using more current than expected, and the service manual blames either shorted wiring or a faulty fan.
At a glance
| Code | 16 |
|---|---|
| Appliance | Freezers |
| What it means | The PC fan is drawing more current than expected, from shorted wiring or a faulty fan. |
Quick comparison with code 15
| Code | Fan current | Manual’s explanation |
|---|---|---|
| 15 | Lower than expected | Open circuit wiring, or faulty fan |
| 16 | Higher than expected | Shorted wiring, or faulty fan |
Either way the wiring runs to a mains-powered module, so the inspection belongs to a technician.
Service steps in the manual
The primary action is to check the PC fan wiring and connections at the fan and at the power module. The secondary action is to check the fan and replace it if it is faulty. No owner checks are listed for this code.
What the PC fan does
A fan like this moves air through its compartment so that the cold produced at the evaporator is spread around. The manual does not describe the PC fan in more detail, and it does not say what you would notice at the door when it misbehaves.
While you wait for the visit
- Note the LED pattern. Fault codes are shown in binary, with each lit LED adding its value to the total.
- If the alarm is sounding, a button press quiets it for the moment.
- Unplugging for a few seconds resets the alarm; otherwise it clears itself after 72 hours.
Related codes
- 15: the low-current reading on the same fan
- 18: the high-current reading on the FC fan
- 12: combined heater and fan current is higher than expected
Freezer repair in San Francisco for Fisher & Paykel
Book through (415) 941-6957 and give us code 16 plus the model number from your unit. Tell us if the fault appeared right after a power cut or a door was opened during start-up.