The heater named in code 13 is the low ambient heater, which the service manual abbreviates LAH. The power module expects a certain current when it switches the heater on. For code 13 the current is lower than expected. The manual’s explanation: either the heater or its wiring is open circuit, or the heater is faulty.
At a glance
| Code | 13 |
|---|---|
| Appliance | Freezers |
| What it means | Low ambient heater is drawing less current than expected (open circuit or faulty heater). |
Open circuit in plain terms
An open circuit means a break in the path, so current cannot flow. A loose plug, a broken wire and a burnt-out heater element all do that, and from the module’s viewpoint they look the same.
The service sequence
- Check the wiring and connections at both ends: at the heater and at the power module.
- Measure the ambient heater resistance. If it is not within limits, replace the heater.
Those are the only two steps the manual lists. It does not give the resistance limits on this page of the code list.
When the code shown can be misleading
The manual tests the low ambient heater first in the 20-second self-test. When the fan and heater connector at the power module is unplugged and a door is opened as soon as the alarm sounds, code 13 is what you see, because the sequence got no further than the first item. A technician is told to wait 20 seconds before opening the door, so the final code is the right one. So if the alarm started at power-up and you opened a door at once, the number you saw may be an early result of the test.
What you can do
- Press a control button to silence the alarm, or unplug for a few seconds to reset it.
- Do not probe the wiring yourself.
- Tell service whether the doors were opened during the alarm.
Neighbouring codes
Heater fault service in San Francisco
Ring (415) 941-6957 and share the code, plus whether the door was opened while the alarm was sounding.