Code 2 is a defrost fault. Active Smart refrigerators periodically melt frost off the evaporator with a heater in the freezer section, and the control gives up on a cycle that runs too long. Code 2 appears when the previous two defrosts were both aborted after 30 minutes.
At a glance
| Code | 2 |
|---|---|
| Appliance | Refrigerators |
| What it means | The previous two defrosts were aborted after 30 minutes. |
What the manual points at
The listed action is to check the defrost heater assembly in the FC, the freezer compartment, and replace it if faulty. The manual refers technicians to its defrost heater flow chart for the detailed test. It does not describe causes beyond that, so nothing else should be assumed.
Facts about forced defrost
- A technician can start a defrost by holding the MODE button and pressing the temperature DOWN button.
- Expect a 2-minute delay before the element begins to heat.
- No defrost happens if the defrost sensor reads above +8 degrees C.
- After a defrost ends, the compressor stays off for 4 minutes, and the fans wait a further 30 seconds after the compressor restarts.
Those timings matter on a service visit, because they explain why nothing seems to happen at first.
At home
Look for symptoms: a freezer section that is icing over, or food getting warm. Do not chip ice off the evaporator or use a hairdryer deep inside the cabinet, since the heater and sensors are in that area. Moving food to a working freezer is the safe choice if the temperature rises. Cutting power for a few seconds resets the alarm.
Related codes
- Code 7: the evaporator sensor reads out of range high.
- Code 8: the evaporator sensor reads out of range low.
Fisher & Paykel freezer repair in San Francisco
To schedule a look at a defrost fault, call (415) 941-6957 and tell us the model number and whether ice has built up.