The evaporator sensor is the third temperature sensor in an Active Smart refrigerator, and the manual also calls its reading the defrost sensor temperature. Code 7 says its resistance is over 45K ohms, outside the range the control accepts.
At a glance
| Code | 7 |
|---|---|
| Appliance | Refrigerators |
| What it means | The evaporator sensor resistance is outside the normal range, above 45K ohms. |
| First thing to try | Check the sensor connection at the power module. |
Why a defrost sensor matters
The manual states that a defrost will not occur if the defrost sensor is above +8 degrees C. So this sensor is part of the decision about when the defrost heater is allowed to work. A bad reading can affect that logic, and it sits close to code 2, the aborted-defrost fault. The manual does not link the two codes, so treat that as context only.
Repair steps given
- Check the sensor connection at the power module.
- Replace the sensor.
How a technician reads it
With the MODE and UP buttons held together, the diagnostic mode opens. Pressing UP twice shows the defrost sensor temperature as LED values. The sum minus 40 is the temperature in degrees C. For example, lit LEDs worth 0.5, 4, 8 and 32 total 44.5, which gives 4.5 degrees C.
Your side of things
The sensor lives in the cold section of the cabinet, so there is no safe owner repair. Keep an eye on frost build-up in the freezer and on food temperature. Pressing a button quiets the alarm for now.