A 4 flashing on a Fisher & Paykel Active Smart refrigerator tells you the problem is wider than one sensor. All of the temperature sensors measured under 660 ohms together. The manual handles this exactly as it handles code 3, the over-range version.
At a glance
| Code | 4 |
|---|---|
| Appliance | Refrigerators |
| What it means | The resistance of all the temperature sensors is outside the normal range, below 660 ohms. |
Three-step procedure
- Primary: check the 6-way RAST connector at the power module.
- Secondary: reterminate the 6-way RAST connector.
- Tertiary: replace the power module.
What low resistance means here
The sensors are thermistors, and their resistance falls as they warm. The warmest figure in the manual’s table, 50 degrees C, is 0.9106 kilohms, which is above 660 ohms. Anything under 660 ohms therefore reads as hotter than the table covers, or as a short between the sensor wires. Since it hits the whole sensor group at once, the manual looks at the common connector and the board before any single sensor.
Sensors in this fridge
There are three the manual names: the PC sensor for the fresh food section, the FC sensor for the freezer, and the evaporator (defrost) sensor. A technician can read each one’s temperature in diagnostic mode, entered by holding MODE and pressing the temperature UP button. The display shows the value as a binary pattern; add up the lit LEDs and subtract 40 to get degrees C. Diagnostic mode ends when MODE is pressed, or after 5 minutes on its own.
For the household
Leave connectors alone. Quiet the alarm with a button if you wish, and keep an eye on food temperature, as a fridge with misread sensors can run too warm or too cold.
More sensor codes
Fisher & Paykel fridge service in San Francisco
Call (415) 941-6957 for a code 4 visit, and mention the model number.