Code 49 narrows the valve problem to one side. The Motor Controller measured a voltage from the valve diagnostic circuit that indicates the cold valve is faulty. The manual calls it the proportional valve, and the code covers Phases 2 to 6.
At a glance
| Code | 49 |
|---|---|
| Appliance | Washers |
| What it means | A voltage from the valve diagnostic circuit indicates the cold (proportional) valve is faulty, most likely from its harness or an open circuit. |
Same procedure as code 48
The manual does not repeat the steps here. It says that for code 49 the service procedure is the one under fault code 48, and gives the same most likely cause: the valve harness has not been connected correctly, or the valve is open circuit.
- Wiring: harness fastened correctly to the valve, pins not bent backwards.
- Valve: coil not open circuit.
- Last resort: replace the Motor Controller module.
A worked example in the manual
The diagnostic section uses code 49 to show how the last fault can be read. In diagnostic mode, the binary code is read from the Wash Progress lights, and the manual adds up 32 + 16 + 1 to reach 49, which it identifies as a cold water valve fault. This is technician-level information and requires entering diagnostic mode with the button sequence for that model.
Spec notes for the cold valve
| Item | Manual value (Series 11) |
|---|---|
| Proportional valve resistance | 64 ohms at 20 C (68 F) |
| Flow rate | 16 litres per minute |
| Supply voltage | 24 volts DC |
Sister valve codes
A note on valve harness plugs
In the Series 11 notes, the manual says the valves come in two possible coil orientations, with identical fittings. A small retaining clip must be released when taking the harness plug off the valve.
San Francisco cold-valve repair
Call (415) 941-6957 and give us the code and model of the washer.