Eco versions of Phase 5 and Phase 6 Smartdrive washers recirculate wash water, and a diverter valve decides whether that water recirculates or goes to drain. Code 51 says the Motor Controller registered a drop in water level during the recirculation phase, so water is being drained instead of recirculated.
At a glance
| Code | 51 |
|---|---|
| Appliance | Washers |
| What it means | On Phase 5 and 6 Eco models water level dropped during recirculation because water drained instead of recirculating, or the valve solenoid was damaged. |
Two primary explanations
- The diverter is draining when it should recirculate.
- Water has been sprayed onto the valve from an external source and caused the solenoid to blow.
The manual’s test
The manual’s test is for a qualified technician only: a technician tests the actuator.
Second suspect
Check for a blockage in the valve itself or a broken hinge mechanism.
Why a diverter can also matter for code 37
The pump blocked error lists the diverter as its fourth possibility: the diverter is stuck in the recirculation mode, so the water level does not change while the machine tries to drain. The manual sends the technician to code 51 for that check.
Next door
- Code 52: more than 6 top-up attempts, which means the valve is not closing or is blocked.
- Code 37: pump blocked error that cross-references this valve.
Resistance figure to compare
The specification section gives the diverter valve resistance as 0.7k to 2.5k ohms. The same window appears under code 52 for the wax solenoid, with the reminder that readings depend on ambient temperature and on when the valve was last actuated.
Eco washer service in San Francisco
For a Fisher & Paykel Eco washer in San Francisco, call (415) 941-6957.