Count matters here: code 52 appears after more than 6 attempts to top up the tub water level. The manual reads that two ways. The diverter valve has not closed and is sending water to drain, or the top-up was not raising the level quickly enough, which suggests a blockage that is also draining. Phase 5 and Phase 6 Eco models only.
At a glance
| Code | 52 |
|---|---|
| Appliance | Washers |
| What it means | More than 6 attempts to top up the tub water level on Phase 5 and 6 Eco models, indicating the diverter valve is not closing or is blocked and draining. |
| Order | Part | Manual’s action |
|---|---|---|
| Primary | Diverter valve | Remove it and check for blockages or a broken hinge mechanism |
| Secondary | Wax solenoid | Check its resistance and look for corrosion on the terminals (a green deposit) |
The resistance window
The expected range is between 0.7k and 2.5k ohms. The manual cautions that values depend on ambient temperature and on when the valve was last actuated. Anything outside the range should be replaced without further debate. The specification section repeats the same 0.7k to 2.5k figure for the diverter valve.
Reading it alongside code 36
Code 36 also complains about too many top-ups, with a limit of 4 during agitate. The difference is the source: code 36 points to siphoning, hose height and leaks, while code 52 points to the diverter. Note that the code 52 count is 6.
Owner view
The diverter has to be removed to be tested, and the solenoid needs a meter. Neither is a user step, and the manual lists no reset.
Other Eco-model codes
San Francisco Eco washer calls
Call (415) 941-6957 and tell us it is an Eco model.