A time-out, in the manual’s words
Code 232 is entered as “COMMS Timeout 5 Sec” for Phase 6. The manual calls it an “IW only problem”: either the Display or the motor controller has not responded in time. So this applies only to IW washers and not to every Phase 6 model.
At a glance
| Code | 232 |
|---|---|
| Appliance | Washers |
| What it means | Phase 6: communications time-out (5 seconds), IW models only; the Display or Motor Controller did not respond in time. |
Two possible culprits
- Primary fault: Display. The action is to replace the Display.
- Secondary fault: Motor controller. The action is to replace the Motor controller.
The order matters because it tells the technician which module to try first. The manual does not offer a way for the owner to tell the two apart.
Where this differs from other communication codes
Some of the manual’s Phase 1 communication entries, such as 4 and 5, begin with turning the power off at the wall for 5 seconds. Code 232 has no such step, so we do not suggest one. Simply switching the machine off and keeping the cover closed is a safe default.
Similar entries
- Code 105: communications time-out between Display and Motor Controller on Phases 2 to 6.
- Code 108: a communications CRC error on the Phase 6 IW display only.
- Code 241: function time-out, with the display crashed.
Replacing or testing
The two actions the manual gives are both replacements, with Display first. The manual gives no way to confirm either one by measuring, and no owner checks.
San Francisco Fisher & Paykel contact
You can reach us at (415) 941-6957. Confirm the washer is an IW model if you can, and give the model number.