The manual gives code 108 exactly one line: a “Coms CRC error,” Phase 6 IW display only, see fault code 106. This page explains what that line does and does not tell you.
At a glance
| Code | 108 |
|---|---|
| Appliance | Washers |
| What it means | Communications CRC error, listed for the Phase 6 IW display only; the manual refers to fault code 106. |
Narrow scope
108 is not a general washer code. It is limited to the Phase 6 Intuitive (IW) display. The manual’s Phase 6 IW model list reads IW811, IW711, IW511, IWL11, IWM11 and MWC11. If your washer is not one of those, a 108 should be treated as unconfirmed.
What CRC means
General background: a CRC, or cyclic redundancy check, is a way for one electronic device to check that a message it received was not corrupted. A CRC error says that messages between the Display and the Motor Controller arrived damaged or did not add up. The manual itself defines nothing beyond the label.
What 106 says
- The Display module is the primary source, to be replaced.
- The Motor Controller module is the secondary source, to be replaced.
- If a new Motor Controller fixes the fault, the original Display is refitted.
What to bring to the call
Because the information is this thin, the call matters more than the page. Give the exact number on the display, the model name, and whether any module was replaced beforehand. The manual cautions that on an IW the wrong Motor Controller may have been fitted.
Related entries
- 106: the procedure this code defers to
- 232: a Phase 6 communications timeout of five seconds, IW only
Intuitive washer service in San Francisco
Call (415) 941-6957 to book.