What the display is telling you
Fisher & Paykel’s manual names 163 the “Valve Reset Pin Connect Fault”. The Motor Controller has sensed that a PCB (circuit board) connection is open circuit. The manual states one consequence: the cold valve cannot operate while that condition exists.
At a glance
| Code | 163 |
|---|---|
| Appliance | Washers |
| What it means | Valve reset pin connect fault: the Motor Controller senses an open-circuit PCB connection and the cold valve cannot operate. |
| First thing to try | The manual names the Motor Controller module as the primary source. |
Reading it
An open circuit means the electrical path is broken, so the controller gets no signal where it expects one. Here that is a board-level connection, not a water-side problem. The code is listed for Phase 4 to 6 machines.
Who fixes what
- The manual names the Motor Controller module as the primary source.
- Its action is to replace the Motor Controller module.
- It lists no owner checks, no reset and no second source for this code.
What not to chase
Because the manual ties the cold valve to this board connection, the cold valve is out of action while 163 is present. The source does not say the valve itself is bad, and it does not suggest looking at the inlet hoses or taps. Do not open the washer to look for the connection; that work belongs with a technician, and the washer should be unplugged for any such work.
Connected valve and wiring codes
- Code 49: the cold (proportional) valve is faulty.
- Code 48: hot and cold valves both faulty, wiring or an open-circuit coil.
- Code 192: another pin-connect fault, for the motor PWM reset.
Scheduling in San Francisco
For Fisher & Paykel washer repair in San Francisco, call (415) 941-6957. Have the model number, the code, and whether the tub filled with cold water ready.