Timeout between two modules
Fault 105 is listed as “Comms Error Time out.” The Display module reports it when communication with the Motor Controller fails. It belongs to Phases 2 to 6 of the Smart Drive washers. Its sibling, 104, is handled by the same procedure.
At a glance
| Code | 105 |
|---|---|
| Appliance | Washers |
| What it means | Communications error (timeout) between the Display module and the Motor Controller on Phases 2 to 6. |
| When to call a technician | The manual lists module replacement, so book service. |
Check the part number first, says the manual
One note sits above the actions: if the product is an IW, the wrong Motor Controller may have been fitted, and the fix is a compatible part. This matters most after a repair. The manual separately warns that modules differ between models and that mixing them means the washer will not work.
Order of suspects
- Display module, primary source. Action: replace it.
- Motor Controller, secondary source. Action: replace it.
- Rotor Position Sensor, tertiary source, Phases 5 and 6 only. Action: replace it; if that corrects the fault, refit the original Display or Motor Controller.
The manual stacks these in a sequence, so parts are changed in turn and the original ones put back if they were not at fault. That is a bench procedure and not an owner task.
When to call
Call if 105 appears. Switch the machine off at the wall in the meantime, and tell the caller if a module or sensor was replaced recently, since the note about wrong parts may apply.
Where else to look
- 104: its sibling error, which refers to the 106 procedure
- 107: the Display module saw the Motor Controller reset unexpectedly
Smart Drive service, San Francisco
Dial (415) 941-6957. Say whether the washer is a standard or Intuitive model, and what was replaced before, if anything.