The water-level sensor in the Phase 5 and 6 machines is called a pressure transducer, abbreviated Ptx in the manual. Fault 64 is raised when the signal it sends is below the expected frequency, specifically under 66 kHz.
At a glance
| Code | 64 |
|---|---|
| Appliance | Washers |
| What it means | The Motor Controller received water-level sensor (pressure transducer) signals below the normal frequency, under 66 kHz (Phases 5 and 6). |
Numbers in the entry
| Detail | Value in the manual |
|---|---|
| Signal frequency | Below 66 kHz |
| Receiver | Motor Controller module |
| Machines | Phase 5 and 6 |
| Primary source | Motor Controller module |
| Action | Replace the Motor Controller module |
A frequency fault, not a level fault
The manual describes the electrical signal from the water level sensor as being below its normal frequency, and gives no hose or filter check for this code.
Models in the manual’s Phase 5 and 6 lists
Phase 5 in the manual’s table includes GW709, GW609 and GWL09, while Phase 6 includes GW711, GW611 and GWL11. Intuitive Display (IW) versions are listed separately for each phase. Look at your model label and match it to these before assuming the entry applies.
What is safe to do
Write down the code and the model number. Do not open the electronics with the washer connected to power. The manual sends the repair to the module, which a technician replaces.
The high-frequency twins
- Fault 65: the same sensor signal, but above 90 kHz
- Fault 66: also above 90 kHz, and it supersedes 65 from V41 Motor Controller code onward
- Fault 58: transducer count at maximum adjustment