The temperature sensor is reading above 110 C, and the manual says this is probably a short circuit in the sensor line. The code is listed for Phases 1 to 6 and applies only to the Intuitive Washer and the GW models.
At a glance
| Code | 41 |
|---|---|
| Appliance | Washers |
| What it means | The temperature sensor (thermistor) is measuring above 110 C, probably due to a short circuit in the sensor line. |
Actions depend on the phase
| Phase | Primary source | Manual’s action |
|---|---|---|
| 1 | Motor Controller | Check the 12 way harness connections; check for moisture in the console area; replace the Motor Controller; then replace the Display Module, and refit the original Motor Controller if the new display fixes it |
| 2 to 4 | Motor Controller | Change the Motor Controller module |
| 5 and 6 | Thermistor | Check the connection from the thermistor to the Motor Controller; check thermistor resistance, which should read 12.5k ohms at 20 degrees C (68 F), and replace it if faulty; then replace the Motor Controller |
Reading the numbers
The thermistor is the temperature sensor for the wash water. The manual describes it as an NTC type with 10,000 ohms at 25 C, and on the ecosmart it sits in the inlet chamber as a separate spare part. A resistance check is a meter job. Anyone doing it must have the washer unplugged.
Not the same as code 10
Code 10 reports the opposite problem: an open circuit, or an ambient temperature below minus 10 C. Code 237 is the Phase 6 form of a continuity problem, which the manual compares to codes 10 and 41.
Temperature sensor repair, San Francisco
Call (415) 941-6957 and give the phase or model if you know it, since the steps above differ by phase.