An extra number for an old fault
Under 240, “Hall Out Of Order. RPS Fault”, the manual says it is the “same as previous Hall Error faults, just an extra fault code for phase 6”. Its direction is to see codes 130 and 131.
At a glance
| Code | 240 |
|---|---|
| Appliance | Washers |
| What it means | Phase 6: Hall out of order; a Rotor Position Sensor fault listed as the same as the earlier Hall error codes. |
Terms
RPS means Rotor Position Sensor. A Hall sensor is a type of sensor that detects the position of a magnet, and here it reports the position of the motor’s rotor to the controller. Reading a rotor position is basic to running the drive motor.
Where the directions are
- Code 130: a single Rotor Position Sensor error, on Phases 1 to 6.
- Code 131: a repetitive Rotor Position Sensor error, on Phases 1 to 6.
The 240 entry gives no steps of its own, so the ones belonging to those two entries are what the manual means. The checks listed under 130 need a meter and an RPS tester, so they are for a technician.
For the homeowner
Switch the washer off at the wall and report the number. Say whether the code came up at the start of a cycle or while spinning if you noticed. The manual does not say, but it helps whoever services the machine to place the fault.
Sensor codes that look alike
Code 243 is another Phase 6 Rotor Position Sensor entry, from a failed stepper test. Code 53 is the rotor sensor step fail found on Phase 2 to 6 machines.
Fisher & Paykel help in San Francisco
Telephone (415) 941-6957 with the model number and the code.