Source: Fisher & Paykel Support: F&P Combi oven: Convection + Microwave fault codes
F101 appears in Fisher & Paykel’s fault table for the convection plus microwave combi oven, and the entry reads simply “Power board”. There is no longer explanation. What the page does give is a short restart routine and a firm instruction on what to do if it fails.
At a glance
| Code | F101 |
|---|---|
| Appliance | Ovens |
| What it means | Fisher & Paykel lists F101 as a power board fault on its convection and microwave combi oven. |
The restart routine
- Wait until the oven has completely cooled and the cooling fan has stopped running.
- Turn the oven off at the power supply.
- Count a full minute, then switch it back on.
- Look at the display. If F101 is gone, carry on as normal.
The oven’s fan is there to bring the temperature down, so the order matters: cool first, then cut power.
If it comes back
Fisher & Paykel says to book a service call when the code returns. A power board is an electronic part inside the appliance that handles the oven’s supply of power, and a combi oven also contains a microwave section, so this is not a panel to open at home.
One thing to watch for
The same number turns up elsewhere. Fisher & Paykel wall ovens also use a separate F1 series for the OB60 wall ovens, described as a clock board fault. Check which kind of oven you have before comparing notes: this page is only about the convection plus microwave combi oven. For the wall oven family see F1XX.
Other board codes on the combi oven
- F211 and related: described as power board errors too
- F102 and related: board communication errors
Combi oven repairs in San Francisco
Call (415) 941-6957, say F101 and give the oven’s model number. Tell us you already tried the one-minute power restart.