An F3 is about temperature. The older DD24/DD60 guide says “temperature sensor failed”, and the support article says “water temperature fault”. Read together they give a practical first question: how hot is the water entering the machine?
At a glance
| Code | F3 / E3 |
|---|---|
| Appliance | DishDrawer Dishwashers |
| What it means | Water temperature fault; temperature sensor failed. |
| When to call a technician | Check the incoming hot water is below 65 C, and book service if a tempering valve is needed. |
The 65 C limit
All three Fisher & Paykel documents agree on the same number. Incoming water should be below 65 C. The Classic-model guide adds the Fahrenheit equivalent, 149 F, for its E3 entry. If your hot supply is set higher than that, the guide says a tempering valve may be needed.
What you can do
- Find out the temperature setting of the water heater feeding the DishDrawer.
- If it is above 65 C, the guide says a tempering valve may be needed. A tempering valve mixes cold water into hot so the outlet stays at a set maximum.
- Do not fit one yourself unless you are comfortable with plumbing. The support article says to book a service for this.
Hot water can scald. Treat any adjustment at the heater with care, and let a plumber or technician set it.
How the Classic guide words the same fault
On Classic panels the matching code is E3, and the guide spells out the plumbing side: you may need a tempering valve on the water supply to make sure incoming water stays below 65 C (149 F). The support article is just as direct, saying a tempering valve may be required and to book a service. Before you phone, find out two things: where the DishDrawer takes its hot water from, and whether anyone has recently raised the setting on the water heater.
If the water is not too hot
Then the code may really be the sensor. The sources do not give owner checks for that case. Neither do they explain how to test the sensor, so leave it to service.
Not the same as F4
F4 names the temperature sensor or the heating element and carries no owner check at all. F3 is the one with the water-temperature clue.
More like this
- E3: the Classic-panel number for this fault
- A09: sanitize temperature not reached, a different current-model code
Water temperature faults, San Francisco service
If you suspect the supply is too hot or F3 stays, call (415) 941-6957 with your heater setting if you know it.